• AMERICAN GEOSERVICES
  • Ph 888-276-4027
  • [email protected]
  • Welcome
  • PORTFOLIO
  • Services
    • Geotechnical Engineering >
      • Geotechnical Engineering
      • Soils Reports/Geotech
      • Slopes/Retaining Walls
      • Drainage/ Groundwater >
        • Surface Drainage
        • LTAR (Long Term Acceptance Rate)
      • Expansive Soils >
        • Fat Clays
      • Collapsible Soils
      • Pile Integrity Test
      • Soil Nailing
      • Slope Stability Analysis
      • Geotechnical Instrumentation & Monitoring
      • Groundwater Monitoring
      • Mining and Quarrying
      • Swimming Pool Structure
    • Geotechnical Explorations >
      • Geotechnical Explorations >
        • Soil Boring and Sampling
      • Geotechnical Site Investigations >
        • Geophysical Soil Exploration
      • Standard Penetration Test
      • Cone Penetration Testing
      • Dynamic Cone Penetration Testing
      • Piezocone Penetrometer
      • Seismic Piezocone Penetration Test
      • Soil Infiltration Testing
      • Inclinometers
    • FOUNDATION ENGINEERING >
      • FOUNDATION ENGINEERING
      • Foundations Types >
        • Machine Foundations
        • Floating Foundations
        • Strip & Pad Foundations
        • HUD Foundations
        • Sheet Piles
        • Drilled Shafts
        • Wind Turbine Foundations
        • Geosynthetic Reinforced Foundations
      • Earthquake Resistant Foundations
      • Foundation Repair >
        • URETEK GEOPOLYMER INJECTION
      • Proprietary Foundation Systems
      • Basement Extensions
      • Forensic Engineering of Foundations
      • Foundation Grouting
      • Construction in Cold Regions
      • Foundation Design For Shipping Container Homes
    • GEOLOGICAL ENGINEERING >
      • Geological Hazard Assesment
      • GEOLOGICAL ENGINEERING
      • Rockfall Hazards
      • Landslides
      • Liquefaction
      • Debris Flow
      • Sinkholes
      • EMBANKMENT OR FILL
    • Septic Engineering >
      • Septic System Feasibility
      • Septic System Design
      • Alternative Septic Systems >
        • Glendon Biofilters
        • Mound Systems
        • Sand Filter System
      • Septic Mound Systems
      • Percolation Testing
      • Percolation Testing
      • Site Evalution for Sewage Systems
    • PHASE I-III ASSESSMENTS
    • ENVIRONMENTAL ASSESSMENTS >
      • Environmental Impact Statement (EIS)
      • Spill Prevention, Control, and Countermeasure (SPCC) Plans
      • Fault Investigation
      • Clean Construction Demolition Debris Certification
    • Site-Specific Seismic Evaluations >
      • Site-Specific Seismic Hazard Evaluation
      • Seismic Site Class Determination
      • Shear Wave Velocity Measurements
      • Response Spectra Analysis
      • SHAKE Analysis
      • Liquefaction Hazard Evaluation
    • BUILDING ASSESSMENTS >
      • Property Condition Assessments
      • Commercial and Residential Building Inspections
      • STRUCTURAL INSPECTION
    • Retaining Walls
    • Shoring
    • Pin Piles
    • Gabion wall
    • HELICAL PIER
    • Structural Retrofitting
    • MANTA RAY ANCHORS
    • GEOPHYSICS
    • PAVEMENTS / PUBLIC WORKS >
      • FLEXIBLE PAVEMENTS
    • SOFTWARE >
      • Retainpro 10
      • Ultrablock walls
  • Contact Us
  • Employment
  • Library
  • Florida Geo Services
  • Blog
  • Landing 2024
  • Welcome
  • PORTFOLIO
  • Services
    • Geotechnical Engineering >
      • Geotechnical Engineering
      • Soils Reports/Geotech
      • Slopes/Retaining Walls
      • Drainage/ Groundwater >
        • Surface Drainage
        • LTAR (Long Term Acceptance Rate)
      • Expansive Soils >
        • Fat Clays
      • Collapsible Soils
      • Pile Integrity Test
      • Soil Nailing
      • Slope Stability Analysis
      • Geotechnical Instrumentation & Monitoring
      • Groundwater Monitoring
      • Mining and Quarrying
      • Swimming Pool Structure
    • Geotechnical Explorations >
      • Geotechnical Explorations >
        • Soil Boring and Sampling
      • Geotechnical Site Investigations >
        • Geophysical Soil Exploration
      • Standard Penetration Test
      • Cone Penetration Testing
      • Dynamic Cone Penetration Testing
      • Piezocone Penetrometer
      • Seismic Piezocone Penetration Test
      • Soil Infiltration Testing
      • Inclinometers
    • FOUNDATION ENGINEERING >
      • FOUNDATION ENGINEERING
      • Foundations Types >
        • Machine Foundations
        • Floating Foundations
        • Strip & Pad Foundations
        • HUD Foundations
        • Sheet Piles
        • Drilled Shafts
        • Wind Turbine Foundations
        • Geosynthetic Reinforced Foundations
      • Earthquake Resistant Foundations
      • Foundation Repair >
        • URETEK GEOPOLYMER INJECTION
      • Proprietary Foundation Systems
      • Basement Extensions
      • Forensic Engineering of Foundations
      • Foundation Grouting
      • Construction in Cold Regions
      • Foundation Design For Shipping Container Homes
    • GEOLOGICAL ENGINEERING >
      • Geological Hazard Assesment
      • GEOLOGICAL ENGINEERING
      • Rockfall Hazards
      • Landslides
      • Liquefaction
      • Debris Flow
      • Sinkholes
      • EMBANKMENT OR FILL
    • Septic Engineering >
      • Septic System Feasibility
      • Septic System Design
      • Alternative Septic Systems >
        • Glendon Biofilters
        • Mound Systems
        • Sand Filter System
      • Septic Mound Systems
      • Percolation Testing
      • Percolation Testing
      • Site Evalution for Sewage Systems
    • PHASE I-III ASSESSMENTS
    • ENVIRONMENTAL ASSESSMENTS >
      • Environmental Impact Statement (EIS)
      • Spill Prevention, Control, and Countermeasure (SPCC) Plans
      • Fault Investigation
      • Clean Construction Demolition Debris Certification
    • Site-Specific Seismic Evaluations >
      • Site-Specific Seismic Hazard Evaluation
      • Seismic Site Class Determination
      • Shear Wave Velocity Measurements
      • Response Spectra Analysis
      • SHAKE Analysis
      • Liquefaction Hazard Evaluation
    • BUILDING ASSESSMENTS >
      • Property Condition Assessments
      • Commercial and Residential Building Inspections
      • STRUCTURAL INSPECTION
    • Retaining Walls
    • Shoring
    • Pin Piles
    • Gabion wall
    • HELICAL PIER
    • Structural Retrofitting
    • MANTA RAY ANCHORS
    • GEOPHYSICS
    • PAVEMENTS / PUBLIC WORKS >
      • FLEXIBLE PAVEMENTS
    • SOFTWARE >
      • Retainpro 10
      • Ultrablock walls
  • Contact Us
  • Employment
  • Library
  • Florida Geo Services
  • Blog
  • Landing 2024

septic system design

What is Septic system?
A septic system is an onsite wastewater treatment system that processes and purifies household waste (effluent). The effluent consists of blackwater (toilet wastes) and greywater (kitchen sink, bathtub and laundry wastes). A septic system has two components: a septic tank and a leachfield or drainfield. Primary treatment occurs in the septic tank, where bacteria digest organic materials in the wastewater. The effluent then flows into the leachfield for secondary treatment. Here, bacteria complete the digestion and purification process as the wastewater slowly leaches or infiltrates into the soil.
​
System Components: The Septic Tank
The septic tank is a “watertight” underground box, usually concrete, about eight feet long, four feet wide, and five feet deep. It has at least a 1,000-gallon capacity for retaining, storing, and treating solids, in addition to releasing effluent into the leachfield, sometimes called a drainfield. As wastewater flows into the tank, heavy solids settle to the bottom into a sludge layer, while grease fats float to the top forming a layer of scum. Between these two layers is a clear zone of liquid called the clarified zone. Found in all three of these layers are billions of bacteria that live naturally in the tank and perform the first phase of treatment to break down solid matter. They digest the solid materials. In the process, gases are produced, which are vented from the septic tank through the plumbing vent on your rooftop.
​
Picture
Picture
The Leach-field:
From the septic tank, partially treated effluent flows into a leach field, which typically has two or more trenches. This is where effluent is naturally purified as it percolates down through the soil. For proper effluent purification, the distance between the trench bottom and the water table should be equal to or greater than the minimum distance allowed by your local health department. The soil acts as a biological filter, removing harmful substances before the effluent reaches the groundwater.
​
Picture
​Infiltrator Chamber Sysytem:
Stone and Pipe Systems:

Old-fashioned systems use gravel or crushed stone in the leaching trenches to create void space to store the effluent and release it slowly. However, such systems are prone to eventual failure as the voids (empty spaces) around the gravel become plugged. This phenomenon occurs over time as solids build up between the stones, limiting infiltration of water into the soil. As the gravel settles, it also tends to compact and accumulate fines (small soil particles), further reducing the infiltration rate.
Your leachfield system is constructed with Infiltrator leaching chambers. These units, manufactured of PolyTuff™, a proprietary blend of polyolefin plastic, interlock together to form a continuous drainage area. This state-of-the-art system offers many advantages over old-fashioned stone and pipe systems. The chambers treat more effluent, more efficiently, in a smaller area. They also have a much greater storage volume than a gravel-filled trench and offer a very large surface area for effluent infiltration into the soil.
​
​The Infiltrator Chamber System:
In 1987, Infiltrator Systems introduced an innovative new technology in septic leachfields, which is now the number one choice in the United States. Infiltrator® chambers are hollow structures that attach end-to-end. They are installed in trenches or beds without gravel (except where local codes require the use of gravel). The entire bottom of the trench is open for unobstructed infiltration of water. The large storage volume within the hollow chambers accommodates peak flows of effluent from the home. Infiltrator chambers also feature patented sidewall louvers that allow lateral leaching of effluent into the soil.
​
​
Picture
Picture
Picture
Advantages of infiltrator chambers over Stone and Pipe Sysytems:
Infiltrator chambers are today’s superior alternative to old-fashioned stone and pipe because they:
 • Provide long-term savings due to longer life and greater operating efficiency
 • Offer worry-free, long-term service with only simple, routine maintenance
 • Protect valuable trees and plantings from damage caused by heavy trucks hauling stone
• Provide greater treatment area to handle more wastewater with higher efficiency
• Offer a “greener” approach utilizing recycled plastic resins to manufacture the chambers
• Are backed by a minimum 1-year warranty and a reputable, service-oriented company
• Can be installed in tight, sloped and curved areas creating less site disruption
• Eliminate the destruction of natural resources and the cost of hauling stone
Picture
Picture
Picture
Picture
Picture

​
​Advantages of septic systems over sewer systems:
Another alternative for septic treatment is sewer systems, which pipe waste to a centralized treatment plant, typically near a river or other body of water for disposal after treatment. Besides avoiding the high cost of sewer lines, septic systems are environmentally superior to sewers because they:
• Provide simple, effective onsite wastewater treatment
• Allow the groundwater to be recharged onsite, which makes more clean water available for use
 • Avoid contamination of local groundwater caused by ageing sewer lines, which leak untreated effluent into the soil.
• Avoid the environmental disaster of raw sewage discharges from treatment plants during floods or processing accidents.

SERVICE AREAS & MAILING ADDRESSES 

COLORADO
Denver, CO
191 University Blvd #375 
Denver, CO 80206
(303) 325-3869
Dial Entire Number
​
Boulder, CO

2810 E. College Ave #102 
Boulder, CO 80303
(303) 325-3869
Dial Entire Nu
mber

​
Fort Collins, CO
​
1281 E Magnolia St D250, Fort Collins, CO 80524 
(303) 325-3869
Dial Entire Number
COLORADO
Colorado Springs, CO
3862 Hodgen Pond Ct Colorado Springs, CO 
(719) 571-9423
Dial Entire Number


Pueblo, CO
140 W. 29th St #311
Pueblo, CO 81008

(719) 571-9423​
Dial Entire Number

Glenwood Springs, CO
1338 Grand Avenue #316
Glenwood Springs, CO
(970) 436-7050

Dial Entire Number​​​

OREGON
Portland, OR
Salem, OR
Lincoln City, OR
Newport, OR
Eugene, OR
Bend, OR

6312 SW Capitol Hwy #231
Portland, OR 97239
(503) 922-3432
​Dial Entire Number
WASHINGTON
Seattle, WA
24 Roy Street #727
Seattle, WA 98109
(206) 418-6634
​Dial Entire Number

Vancouver, WA
Longview, WA
​41105 NE Cedar Ridge Rd
​Amboy, WA 98601
(360) 437-6369
Dial Entire Number​
​FLORIDA
Jacksonville, FL
6001 Argyle Forest Blvd,
Suite 21
Jacksonville, FL 32244

(904) 512-0085
Dial Entire Number

Orlando, FL
10524 Moss Park Rd,
Suite 204 #701

Orlando, FL 32832
(407) 362-1940
Dial Entire Number

FLORIDA
Tampa, FL
701 S Howard Ave #106, Tampa, FL 33606
(813) 569-7704
Dial Entire Number


​Miami, FL
3725 W. Flaglen St,
Miami, FL 33134
(305) 677-9494
​Dial Entire Number

Upcoming: INDIA

Pune, India
Bungalow 21, Acacia Garden 2 Magarpatta City, Hadapsar
India
Maharashtra
Pune
​411028



Copyright 2016 American GeoServices, LLC.  All rights reserved.